Stability Walk in Chamber/ Temp. and Humidity Test Chamber for Automotive Vehicle
Guangdong Komeg Industrial Co., Ltd.- After-sales Service:1 Year
- Power Supply:380V ,220V
- Certification:CE, ISO
- Warranty:1 Year
- Volume(M3):12.9
- System:Balanced & Humidity Control System
Base Info
- Model NO.:KMHW-21
- Temp. Range:-60 Oc~+120 Oc
- Humidity Range:10-95%R.H.
- Temp. Constancy:+,-0.5oc
- Humidity Constancy:+,-2.5%R.H.
- Temp. Uniformity:+,-2.0oc
- Humidity Uniformity:+,-5.0%R.H.
- Heat up Time:+20oc~+80oc Within 60mins
- Pull Down Time:+20 Oc~-55 Oc Within 90mins
- Transport Package:Strong Plywood Case, Meet International Standard
- Specification:Standard and Customized
- Trademark:KOMEG
- Origin:Dongguan, China
- HS Code:90321000
- Production Capacity:1000 Sets Per Year
Description
Walk-In ChambersSPECIFICATIONS Note: We reserve the right to change specifications without prior notice Model KMHW- 4 6 8 13 17 21 Volume(m ³ ) 9 12.9 16.8 16.8 35.2 43.3 Interior Dimensions W(mm) 2100 3000 3900 3000 3900 4800 H(mm) 2100 2100 2100 2100 2100 2100 D(mm) 2050 2050 2050 4300 4300 4300 Exterior Dimensions W(mm) 3250 4160 5050 5050 5050 5950 H(mm) 2350 2350 2350 2350 2350 2350 D(mm) 2250 2250 2250 2250 4500 4500 Safety Devices(standard) No fuse breaker, overpressure overheat and over current protection for compressor,
over-temperature protection,
overload protection for the blower, dry heat protection Standard accessories Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1,
status indicator Control System Balanced Temperature & Humidity Control System Refrigeration system Water Cooled Semi-hermetic compressor,
single stage or cascade refrigeration system, CFC free refrigerant ( HFC-507 and HFC-23 ) Controller Panel 7-inch LCD Touch panel, Chinese or English display selectable Operation model Program or fixpoint running Memory capacity 120 programs,1200steps, all repeat 999 cycles, part repeat 99 cycles Accuracy Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit Input Temp.:pt-100, Humidity:pt-100 or ~ 5V DCV Comm.port RS-232 or RS-485 (Softawre is an option) Temp. range Maximum : 80 ºC, 120 ºC; Minimum : -60 ºC, -50 ºC, -40 ºC , -30 ºC, -20 ºC , -10 ºC, 0 ºC Humidity Range 10 %, 20% , 30% ~ 95% Temp. constancy ±0.5 ºC Humidity constancy ±2.5 % R.H Temp. uniformity ±2.0 ºC Humidity uniformity ±5.0 % R.H Ambient Temp. +5 ºC~ +35 ºC Wiring method AC 380±10 % 50Hz,3 phase 4 wires +Ground Wires Heat uptime +20 ºC~ +80 ºC ,Within 60 min Pull downtime +20 ºC~ -55 ºC -40 ºC -20 ºC -10 ºC ,Within 120 or 90 or 60 min Interior material Stainless Steel Plate(SUS 304) Exterior material Baked Painting Steel Or Stainless steel(SUS304) Insulation material Rigid polyurethane foam Door size (mm) Single wing : W800*H1800 ; Double wing : W1600*H1800 ; Note:1. We reserve the right to change specifications without prior notice
2.Customized sizes and configurations available 
Control method and characteristics:
Precision microcomputer control temperature and humidity system, with PID, control the refrigerant flow to make the system's heating/humidification reduction, to achieve low power consumption, energy-saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.
Standard Met and Implemented:
GB/Bb T2423.2-89 high-temperature test method
GB2423.1-89 test A: low-temperature test method 6
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature



After-sale service
over-temperature protection,
overload protection for the blower, dry heat protection
status indicator
single stage or cascade refrigeration system,
2.Customized sizes and configurations available

Control method and characteristics:
Precision microcomputer control temperature and humidity system, with PID, control the refrigerant flow to make the system's heating/humidification reduction, to achieve low power consumption, energy-saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.
Standard Met and Implemented:
GB/Bb T2423.2-89 high-temperature test method
GB2423.1-89 test A: low-temperature test method 6
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature



After-sale service
If you face any problems in future during the testing process we promise we will give you a reply within 48 hours and the solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by the customer.