Test Instrument

Cdsc-500A Auto Software DSC Differential Scanning Calorimeter

Jinan Chenji International Trade Co., Ltd.
  • After-sales Service:Whole Life
  • Warranty:12 Months
  • Max Diameter of Workpiece:<500mm
  • Mass Scope of Workpiece:<900kg
  • Type:Material Testing Machine
  • Maxcapacity:Heating

Base Info

  • Model NO.:CDSC-500A
  • Accuracy Grade:1
  • Load Way:Without
  • Loading Method:Heating
  • Display:Digital
  • Control:Computer Control
  • Weight:0-100Kg
  • Power Source:AC220V
  • Oil Cylinder Position:by Electric
  • The Range of Temperature:Room Temperature to 800 ºC
  • The Temperature Resolution:0.1 ºC3: Heating Rate: 0.1 ~ 80 ºC , Min
  • DSC Range:0 ~ + 500 MW
  • DSC Resolution:0.01 MW
  • DSC Sensitivity:0.1 MW
  • Working Power Supply:AC 220 V, 50 Hz or Custom
  • Name 1:Differential Scanning Calorimeter
  • Key Point:Dcs
  • Control Way:Computer
  • Transport Package:Standrd Ocean Ship
  • Specification:500*500*600
  • Trademark:Chenji or OEM ODM
  • Origin:Jinan or Others

Description

Basic Info.

Model NO. CDSC-500A Accuracy Grade 1 Load Way Without Loading Method Heating Display Digital Control Computer Control Weight 0-100Kg Power Source AC220V Oil Cylinder Position by Electric The Range of Temperature Room Temperature to 800 ºC The Temperature Resolution 0.1 ºC3: Heating Rate: 0.1 ~ 80 ºC / Min DSC Range 0 ~ + 500 MW DSC Resolution 0.01 MW DSC Sensitivity 0.1 MW Working Power Supply AC 220 V, 50 Hz or Custom Name 1 Differential Scanning Calorimeter Key Point Dcs Control Way Computer Transport Package Standrd Ocean Ship Specification 500*500*600 Trademark Chenji or OEM ODM Origin Jinan or Others

Product Description

CDSC-500A Auto Software DSC Differential Scanning Calorimeter
Cdsc-500A Auto Software DSC Differential Scanning Calorimeter
1. Functions:
CDSC-500A can be employed for the characterization of a great variety of materials. It is used in polymers; and here not only in plastics and rubber processing, but also in the pharmaceutical and, food packaging and technical textiles.
Differential scanning calorimeter (DSC) as a programmable temperature of the heating effect of the classical thermal analysis method, in today's all kinds of material and in the field of chemical industry research and development, process optimization, and quality control, quality control and failure analysis, etc. Various kinds of occasions have been widely applied. Using DSC method, we can accurately test the oxidation induction time of materials. Widely used in plastic, rubber, paint, food, medicine, biological organisms, inorganic materials, metal materials and composite materials

standards-compliant:
GB17391-1998, ISO/CD11357/6
Characteristics
Touch screen display, display information is very more, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, all kinds of switch state
USB communication interface, generality is strong, reliable communication don't interrupt, support the restore connection function.
Furnace structure is compact, arbitrary adjustable cooling rate.
Improved installation process, all adopt the machinery fixed way, completely to avoid contamination of furnace inside colloid to differential thermal signal.
Double temperature probe, make sure the height of the sample temperature measurement repeatability. Temperature sensor is installed on furnace walls all the way, used for PID control of the furnace body temperature, but due to the temperature of thermal inertia, conduction to the temperature on the sample have some deviation, and deviation degree of four seasons is different, therefore, with one temperature probe temperature control and temperature measurement, differential thermal signals and temperature signals, the error is larger; The instrument in the bottom of the sample how to install a temperature probe, used to measure the real temperature of the sample, and used our special temperature control technology, control the temperature of furnace wall temperature to reach the set temperature.
Digital gas mass flow meter atmosphere automatic switching two way traffic, fast switching and stable time is short.
Standard samples, convenient customer constant temperature correction coefficient.
Software adaptive resolution of computer screens, each software automatically according to the computer screen size to adjust the curve display mode. Support for notebook, desktop; Support the Win2000, XP, VISTA, Windows 7 operating system, etc
Support user programming procedures, to achieve fully automated measuring step. Software provides dozens of commands, users can according to your own measurement steps, and combined the orders, and save. Complex operation is simplified into a key operation.

Technical Parameter
1: the range of temperature: room temperature to 800 ºC 
2: the temperature resolution: 0.1 ºC3: heating rate: 0.1 ~ 80 ºC / min
4: DSC range: 0 ~ + 500 mw    
5: DSC resolution: 0.01 mW
6: DSC sensitivity: 0.1 mW
7: working power supply: AC 220 v, 50 hz or custom