Test Instrument

0~16kV Cable Fault Location System With 20km Locating Distance

HV Hipot Electric Co., Ltd.
  • Connectors:USB
  • Usage:Cable Testing
  • Test Region:LCD Screen
  • Cable Type:HV Cable, Communication Cable
  • Power:Electricity
  • Certification:ISO

Base Info

  • Model NO.:GD-2136L
  • Customized:Non-Customized
  • Color:Yellow
  • Power Supply:AC 220V; 50Hz
  • Output voltage:DC 0-16kV (adjustable)
  • Rated power:1kVA
  • Max.energy:1024J, 8UF
  • DC flashover voltage:16kV
  • DC flashover current:63mA
  • Max.impulse current:500mA
  • Discharging method:DC HV, one time, cycle
  • Cycle discharging time:3-6 seconds
  • Transport Package:Wooden Case
  • Specification:ISO, SGS
  • Trademark:HV Hipot
  • Origin:China
  • HS Code:9030332000
  • Production Capacity:1000PCS,Year

Description

Tracing and locating distancelocal cable 3km, other cable up to 20kmFault impedance resistance0-5MΩLocating accuracy≤±10cmDetection cable depth<3m
 
3. GD-2133 Cable Fault Detector
It can test faults of short circuit, grounding, high impedance leakage, high impedance flashover fault and cable's poor connection, disconnection for all kinds of power cables (voltage degree 1kV-35kV) , local cable, communication cable,coaxial-cable and metal overhead line.
It also can measure cable's length and propagation speed of electric wave speed on the cable. 
 
Features

1. Safe, prompt and accurate testing. It uses LV impulse method and HV flashover detection,which test all kinds of cable faults.
2. Using high speed data sampling technology. A/D sampling speed is 100Mhz.
3. Wave form and data automatically display on big LCD screen.
4. Wave form and parameter storage function.
5. Function of comparing testing waveform of cable fault with normal waveform.
6. Wave form extending function.
7. Directly show fault point and testing point direct distance or relative distance.
8. Modify speed of propagation any time according to different testing cables.
9. Built-in rechargeable battery. Small size, portable to carry.


Specifications

 
Max.testing distance15km(Open wire up to 100km) according to customer's requirements.
Blind detection1m
Resolution1m
Power consumption5VA
Environmental temperature0-40ºC(limit temperature:-10ºC-50ºC)
Relative humidity40ºC(20~90)%RH
Atmospheric pressure86-106Kpa
Size275*220*160mm
Weight1.8kg


Other accessories

Other accessories include AF Stethoscope, Headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod