0~16kV Cable Fault Location System With 20km Locating Distance
HV Hipot Electric Co., Ltd.- Connectors:USB
- Usage:Cable Testing
- Test Region:LCD Screen
- Cable Type:HV Cable, Communication Cable
- Power:Electricity
- Certification:ISO
Base Info
- Model NO.:GD-2136L
- Customized:Non-Customized
- Color:Yellow
- Power Supply:AC 220V; 50Hz
- Output voltage:DC 0-16kV (adjustable)
- Rated power:1kVA
- Max.energy:1024J, 8UF
- DC flashover voltage:16kV
- DC flashover current:63mA
- Max.impulse current:500mA
- Discharging method:DC HV, one time, cycle
- Cycle discharging time:3-6 seconds
- Transport Package:Wooden Case
- Specification:ISO, SGS
- Trademark:HV Hipot
- Origin:China
- HS Code:9030332000
- Production Capacity:1000PCS,Year
Description
3. GD-2133 Cable Fault Detector
It can test faults of short circuit, grounding, high impedance leakage, high impedance flashover fault and cable's poor connection, disconnection for all kinds of power cables (voltage degree 1kV-35kV) , local cable, communication cable,coaxial-cable and metal overhead line.
It also can measure cable's length and propagation speed of electric wave speed on the cable.
Features
1. Safe, prompt and accurate testing. It uses LV impulse method and HV flashover detection,which test all kinds of cable faults.
2. Using high speed data sampling technology. A/D sampling speed is 100Mhz.
3. Wave form and data automatically display on big LCD screen.
4. Wave form and parameter storage function.
5. Function of comparing testing waveform of cable fault with normal waveform.
6. Wave form extending function.
7. Directly show fault point and testing point direct distance or relative distance.
8. Modify speed of propagation any time according to different testing cables.
9. Built-in rechargeable battery. Small size, portable to carry.
Specifications
Max.testing distance | 15km(Open wire up to 100km) according to customer's requirements. |
Blind detection | 1m |
Resolution | 1m |
Power consumption | 5VA |
Environmental temperature | 0-40ºC(limit temperature:-10ºC-50ºC) |
Relative humidity | 40ºC(20~90)%RH |
Atmospheric pressure | 86-106Kpa |
Size | 275*220*160mm |
Weight | 1.8kg |
Other accessories
Other accessories include AF Stethoscope, Headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod