Automatic Air Release Value of Insulating Oil Testing Equipment
200 Sets/MonthAfter Sales Service * The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.* We guarantee the maintenance time no more than 3 working days and response time within 8 hour.* We bui
-
Strength Test/ Universal Testing Machine/ Electronic Testing Machine with Computer Control
180kgThe standard accessories:1,load sensor: USA keli high precision sensor 20kN.1 set2,testing software: 64bit test board +Chinese and English interface.1 set3,motor control:Taiwan delta B2servo motor +servo driver1 set4,deceleration system: GWD precision reducer1 set5,drive rod: Taiwan TBI high-pr
-
Elmendorf Tearing Tester Tear Tester ISO6383
Extended ApplicationsHeavy Package BagsRubber GlovesWrapping FilmsTechnical SpecificationsSpecificationsFTS-01Pendulum Capacity200 gf, 400 gf, 800 gf, 1600 gf, 3200 gf, 6400 gfSample HolderPneumaticPendulum Release PneumaticGas Supply Pressure0.6MPa (Not in Supply Scope)Port SizeΦ4 mm PU TubingI
-
500kv Frequency Varied Cable Withstand Voltage AC Resonant Test Machine
1.Exiting transformer 12KVA: 1Unit2.Voltage divider120KV: 1Unit3.Variable frequency power source 12KW: 1 Unit4.HV reactor54KVA/27KV: 4 Units IV.Detailed PhotosV.Company InformationHuaZheng Electric Manufacturing (Baoding) Co.,Ltdis the supplier of the State Grid in China.It me
-
300j Computerized Automatic Charpy Pendulum Impact Strength Testing Machine
Computer Control AutomaticMax. Impact Energy300 J/ 150 J500 J/ 250 J500 J/ 750 JMin. Reading Values1 J2 JImpactSpeed5.2m/s5.4m/s5.9m/sPre-risingAngleOfThePendulum150°AngleAccuracy±0.1°SpecimenBearerSpan40+0.2mmRoundAngleOfTheJawR1.0~1.5mmRoundAngleOfImpactEdgeR 2.0~2.5 mm(Special Orde
-
Coc ASTM D93 Automated Oil Flash Point Tester (TPC-3000)
Basic Info. Model NO. TPC-3000
-
Rated capacity:10kVAInput voltage:AC220VOutput voltage range:0-150kV, 66mA AC RMS0-210kV, 47mA, DC RMSRating100%rated-1minute , 50%-continuousOutput controlAutomatic & manual controlVoltage measuring error<±(0.2%U+0.02%Umax) U is reading value, Umax is upper limit value of measuring ra
-
Microcomputer Digital Secondary Current Injection 6-Phase Electric Protection Relay Test
Overview Product DescriptionHigh Power 6-phase Protection Relay Test SystemSetting Range6-Phase AC(L-N)6x0…40A3-Phase AC(L-N)3x0…80A1-Phase AC(LL-LN)1x0…240ADC(L-N)6x0…±20 APower6-Phase AC(L-N)6x300VA At 40A3-Phase AC(L-N)3x450VA At 80A1-Phase AC(LL-