Sofa Mattress Flame Retardant Flammability Testing Equipment
Wenzhou Darong Textile Instrument Co. Ltd- After-sales Service:1 Year
- Warranty:1 Year
- Max Diameter of Workpiece:<500mm
- Mass Scope of Workpiece:<900kg
- Type:Flammability Testing Machine
- Maxcapacity:<1000KN
Base Info
- Model NO.:YG(B)815S
- Accuracy Grade:0.5
- Load Way:Electronic Load
- Loading Method:Static Load
- Display:Digital
- Control:Computer Control
- Weight:0-100Kg
- Power Source:AC220V
- Oil Cylinder Position:Under
- Gas Source:Propane or Butane
- Ignition Time Setting:0-999.9s
- Automatic Record on Time:0-6553.5s
- Combustion Speed:0-9999mm,Min
- Transport Package:Export Package
- Trademark:DARONG
- Origin:China
- HS Code:9024800000
- Production Capacity:2000sets,Month
Description
The outer diameter of the flamethrower is (8 ± 0.1) mm, the inner diameter is (6.5 ± 0.1) mm, and the length is (200 ± 5) mm. The inner diameter of the hose connecting the gas and the fire pipe is (7.0±1) mm and the length is (2.5 to 3.0) m. Butane gas output pressure is about 28mbar (2.8kPa).
During the test, the No. 1 fire source should be stable for at least 2 minutes, and the distance between the test position and the nearest edge or the last position should not be less than 50mm; the No. 2 and No. 3 fire sources should be stable for at least 4 minutes, and the distance between the test position and the nearest edge or the last position should be at least 4 minutes. Not less than 100mm.2#:
Butane flame Gas flow:25ºC (160±5)mL/min
20ºC (157±5)mL/min
Flame height:Appro. 145mm
Burning time:(40±1)s 3#:
Butane flame Gas flow:25ºC (350±10)mL/min
20ºC (344±10)mL/min
Flame height:Appro. 240mm
Burning time:(70±1)s









During the test, the No. 1 fire source should be stable for at least 2 minutes, and the distance between the test position and the nearest edge or the last position should not be less than 50mm; the No. 2 and No. 3 fire sources should be stable for at least 4 minutes, and the distance between the test position and the nearest edge or the last position should be at least 4 minutes. Not less than 100mm.
Butane flame
20ºC (157±5)mL/min
Flame height:Appro. 145mm
Burning time:(40±1)s
Butane flame
20ºC (344±10)mL/min
Flame height:Appro. 240mm
Burning time:(70±1)s