-
Textile 45 Degree Flammability Testing Machine ASTM D 1230
Product nameTextile 45 Degree Flammability Testing MachineStandardNFPA 702, ASTM D 1230, ASTM F 963, 16 CFR 16.10, CATB 1PowerAC 220V, 50/60Hz, 5ASample holderoneInstructionprovidedToolvacuum cleaners, propane gasWeight30kgSize750mm(W) *300mm(D)*900mm(H)
-
Needle Flame Tester for Plastics IEC 60695
Product NameNeedle Flame Tester for Plastics IEC 60695MaterialStainless steelThe combustion gaesThe combustion gaesThe burner angle90° 45°Subplatewhite pine plank ( 10mm),Surface covered by standard silk paper200mm ± 5mm below the flameTemperature range0--1000 ºCThe flame temper
-
Emulsified Asphalt Paving Slurry Seal Mixture Ratio Consistency Tester
1. The metal truncated cone: Upper caliber:38 mm; lower caliber: 89 mm; high 76 mm;2. The metal plate:4 mm thick, with aconcentric calibration line, spacing: 0.5 cm.3. Dimensions:235 mm ×235 mm ×80 mm (length ×width ×height).III. Optional accessories1. Balance: Weighing 1000g
-
High Precision Coal Calorific Value Meter Oxygen Bomb Calorimeter ASTM D240
No.ItemSpecifications1Heat capacity14000~15000J/K2Temperature measurement range10 ~35ºC3Temperature resolution0.001 ºC4Repeatability error≤0.2 %(Grade C)5Endured pressure in oxygen bomb20 MPa6Operation environment temperature15 ~28ºC(Ambient temperature); Temperature fluctuation is
-
Harmonic Power Analyzer Three Phase Power Quality Analyzer
0.15%INa.In the table above, Un refers to nominal voltage, Uh is measured value of harmonic voltage; ln refers to rated current, Ih ismeasured value of harmonic current.b. Measurement range of instrument of class A: 0~2500Hz, used for accurate measurement. Measured phase error is less than ±5
-
Portable Three Phase Power Quality Measuring Instrument Harmonic Analyzer
0.15%INa.In the table above, Un refers to nominal voltage, Uh is measured value of harmonic voltage; ln refers to rated current, Ih ismeasured value of harmonic current.b. Measurement range of instrument of class A: 0~2500Hz, used for accurate measurement. Measured phase error is less than ±5
-
Three Phase Power Quality and Harmonics Analyzer
0.15%INa.In the table above, Un refers to nominal voltage, Uh is measured value of harmonic voltage; ln refers to rated current, Ih ismeasured value of harmonic current.b. Measurement range of instrument of class A: 0~2500Hz, used for accurate measurement. Measured phase error is less than ±5
-
Automatic Water Content Tester Volumetric Mothod Karl Fischer Mositure Titrator ASTM E203
Measurement Range0.001%-100%(water phase content)Resolution1μgTitration repeatability≤0.01Titration linear coefficient≥0.998Error≤2%Test time2-5minData storage100 groupsBurette200ml automatic buretteTitration accuracy0.001mlEnd-point Delay Time10s-300s adjustable continuouslyPower Supply