Test Instrument

HVC-10 Portable High Voltage Tester Voltage Detector

HV Hipot Electric Co., Ltd.
  • Using temperature:0ºC~40ºC
  • Storage temperature:-10ºC~50ºC
  • Relative humidity:<85%
  • Measurement range:AC 0~10kV
  • Transport Package:Standard Expor Twooden Box
  • Specification:ISO, SGS

Base Info

  • Model NO.:HVC-10
  • Trademark:HV Hipot
  • Origin:Wuhan, China
  • Production Capacity:5000set,Year

Description

Basic Info.

Model NO. HVC-10 Trademark HV Hipot Origin Wuhan, China Production Capacity 5000set/Year

Product Description

HVC-10 Portable High Voltage Tester Voltage Detector

I. General Information

The HVC-10 portable high voltage tester is used to measure high voltages of 6kV, 10kV, 35kV, 110kV, 220kV, 330kV and 500 kV. The insulating tube is made of epoxy phenolic laminated glass resin after hot pressing. It has high mechanical strength and electrical properties, and has the characteristics of anti bending resistance, impact resistance, moisture resistance, and high insulation. See Table 1 and Table 2 for the material characteristics and withstand voltage of insulating rods.

A high-voltage attenuation resistor is installed in the insulating tube, which converts the high voltage into a low voltage signal, and then enters the multimeter and displays the measured voltage value. Because the whole device has only one insulating rod and a multimeter, it is very convenient to carry and use, and can meet the high voltage measurement of ordinary requirements.
 
ItemUnitIndex
Heat resistance is not lower thanºC200
Impact resistance (longitudinal) is not lower thanmpa/cm147
Bending resistance (longitudinal) is not lower thanmpa343
Surface resistivity (after water immersion) is not lower thanΩ10*1011
Volume resistivity (normal) is not lower thanΩ/cm10*1031
Table 1 Material characteristics of insulating rods
 
Insulation rod rated voltage(kV)1035
Impulse withstand voltage(kV)100150
Detection length0.40.6
Table 2 Impulse withstand voltage of insulating rod

II. Product Schematic Diagram

III. Specifications
 
  1. Using temperature: 0ºC~40ºC
  2. Storage temperature: -10ºC~50ºC
  3. Relative humidity: <85%
  4. Measurement range: AC 0~10kV
  5. Measurement meter: multimeter
  6. Measurement accuracy:< ±(5%+3 digitals)
  7. Weight :2.0kg
This product is composed of an insulated rod and a special multimeter. The insulated rod has a high voltage partial resistance. During measurement, the high voltage passes through the internal high voltage division resistance of the insulated rod and decay to a low voltage signal. The division ratio is 1000: 1.

Technical data of insulating tube
Rated voltage(kV)Attenuation resistance
(MΩ)
Insulated rod
effective length(m)
Insulated rod
shrink length(m)
Insulated rod
extension length(m)
Number of knots
61-2.40.40.61.54
101.5-40.70.62.04
355-140.90.62.55

Insulating rod effective length: when using the electroscope, the minimum distance from the electroscope to the hand holding point.
Insulated rod shrinkage length: The approximate length of the retractable insulated rod used in the electroscope after contraction.
Insulation rod extension length: the approximate length of the telescopic insulation rod used in the electroscope after being extended.
HVC-10 Portable High Voltage Tester Voltage Detector
HVC-10 Portable High Voltage Tester Voltage Detector
HVC-10 Portable High Voltage Tester Voltage Detector
HVC-10 Portable High Voltage Tester Voltage Detector