  • Standards:IEC 60695
  • Burner Angle:90° 45°
  • Temperature Range:0--1000 ºC
  • The Flame Height:12mm
  • Dimensions:L1120 * W520 * H1250mm
  • Power Supply:220V , AC, 50Hz

Base Info

  • Model NO.:GD-60695
  • Warranty:1 Year
  • Oversae Training:Available
  • Transport Package:Plywood Case
  • Trademark:Gold
  • Origin:China
  • HS Code:9031809090
  • Production Capacity:10 Sets,2 Month

Description

Basic Info.

Model NO. GD-60695 Warranty 1 Year Oversae Training Available Transport Package Plywood Case Trademark Gold Origin China HS Code 9031809090 Production Capacity 10 Sets/2 Month

Product Description

             IEC 60695 Needle Flame Test Machine
Introduction:

Needle Flame Tester is made in accordance with national standards GB4706.1-1998 .The tester applies for lighting, low-voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, electrical connectors, accessories and other electrical and electronic equipment and parts, component research, production and quality control departments and insulating materials , plastic or other solid combustible materials industry to carry on  small-flaming ignition experiments.

Needle flame tester uses standard size (Φ0.9mm) needle burner .and burns the sample with specific gas (butane) at the angle of 45 °.It determines the ignition risk of  the small-flame caused by fault conditions in the equipment by testing the sample burning situation ,burning time and burning  length

Standard:

GB4706.1,

GB5169.5-2008, 

IEC60695-2-2

IEC60695-11-5 etc.

Technical Parameters:

1. Needle burner is made of stainless steel

2. The burner angle: 90° 45°

3. The combustion gases: 95% butane gas or propane gas;

4. Subplate: white pine plank ( 10mm),

   Surface covered by   standard silk paper

   200mm ± 5mm below the flame

5. Temperature range: 0--1000 ºC

6. The flame temperature requirements:  100 ± 2 ºC ~ 700 ºC ± 3 ºC,

     Heating rise time:  23.5 ± 1.0s;

7. The flame height: 12mm ± 1mm;

8. Ignition time: 0s ~ 999.9s adjustable, generally  30s;

9.  Burning time: 0s ~ 999.9s, automatic recording, manual pause;

10. Test Space: ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements);

11. Temperature sensor: K-type insulation-sheathed thermocouple (Φ0.5mm)

12. Automatic test program , independent exhausting system;

13. Dimensions: L1120 * W520 * H1250mm,

       The diameter of exhaust :Φ100mm;

14. Test power supply: 220V / AC, 50Hz