Test Instrument

PLC Control Three-phase Primary Current Injection Test Set with temperature rise test

HV Hipot Electric Co., Ltd.
  • Type:Universal Testing Machine
  • Load Way:Electronic Load
  • Loading Method:Dynamic Load
  • Control:Computer Control
  • Weight:100-500Kg
  • Power Source:AC220V

Base Info

  • Model NO.:GDSL-A-500
  • Model number:GDSL-A-500
  • Power supply:AC380V
  • Frequency:50Hz
  • Output current:AC 0-500A
  • Output capacity:15kVA
  • Output voltage:AC 10V
  • Duty cycle:8hours(according to customer demand)
  • Current accuracy:1.5%
  • Warranty:1 year
  • Transport Package:Wooden Case (2 Packages)
  • Specification:ISO, SGS
  • Trademark:HV Hipot
  • Origin:Wuhan China
  • HS Code:9030339000
  • Production Capacity:5000 Sets,Year

Description

Model

GDSL-A-500

Max. Output current

AC Single-phase 500A*3 groups

Circuit mode

Electric voltage regulator with special craft

AC Input

Phase line

3Φ4W+G

Voltage

380V±10%, 50Hz±2% 3Φ4W

Rated current

109A*3

 

 

 

 

 

 

 

 

 

Output

 

Phase line

3Φ4W

Voltage

0~10V Auto switching

Current

AC 0~500A continuous adjustment, stepless speed regulation;

3-phase can output at one time, single-phase output, also split phase output

Two kinds of output, manual mode and auto mode. 

Rated capacity

5kVA*3

Output terminal

Wire terminals

Protection

The electronic circuit quickly detects over-voltage, over-current, over-temperature, and lack of

equal automatic trip protection and alarm devices. The non-test state voltage is zero and the current is zero.

Display& Setting

Voltmeter display

True color LCD and digital display (display accuracy: 0.1V, display error: ≤1% ± 1 digital)

Ammeter display

True color LCD and digital display (5 digit digital display, display accuracy 0.1A, display error: ≤1% ± 1 digital)

System

Machine efficiency

≥90%

Withstand voltage insulation resistance

AC 1800V 1 minute, 20 megohms

Cooling device

forced fan cooling

Noise

<60dB (1mm in front of the machine)

Transformer accuracy

0.2 class

Protection level

IP20

Working environment

Working mode

long-term temperature rise experiment

Temperature

-10°C-50°C

Humidity

0-90% (non-condensing state)

Altitude

Below 1500m

Shape

Structure

Integration

 

Size

1.25*1.05*1.6 m

 

Bus bar

output is calculated as 2 currents per square

Temperature inspection

16-way module

Expandable

Class A thermocouple

 

About us

 

PLC Control Three-phase Primary Current Injection Test Set with temperature rise test
PLC Control Three-phase Primary Current Injection Test Set with temperature rise test
PLC Control Three-phase Primary Current Injection Test Set with temperature rise test
PLC Control Three-phase Primary Current Injection Test Set with temperature rise test