PLC Control Three-phase Primary Current Injection Test Set with temperature rise test
HV Hipot Electric Co., Ltd.- Type:Universal Testing Machine
- Load Way:Electronic Load
- Loading Method:Dynamic Load
- Control:Computer Control
- Weight:100-500Kg
- Power Source:AC220V
Base Info
- Model NO.:GDSL-A-500
- Model number:GDSL-A-500
- Power supply:AC380V
- Frequency:50Hz
- Output current:AC 0-500A
- Output capacity:15kVA
- Output voltage:AC 10V
- Duty cycle:8hours(according to customer demand)
- Current accuracy:1.5%
- Warranty:1 year
- Transport Package:Wooden Case (2 Packages)
- Specification:ISO, SGS
- Trademark:HV Hipot
- Origin:Wuhan China
- HS Code:9030339000
- Production Capacity:5000 Sets,Year
Description
Model
GDSL-A-500
Max. Output current
AC Single-phase 500A*3 groups
Circuit mode
Electric voltage regulator with special craft
AC Input
Phase line
3Φ4W+G
Voltage
380V±10%, 50Hz±2% 3Φ4W
Rated current
109A*3
Output
Phase line
3Φ4W
Voltage
0~10V Auto switching
Current
AC 0~500A continuous adjustment, stepless speed regulation;
3-phase can output at one time, single-phase output, also split phase output
Two kinds of output, manual mode and auto mode.
Rated capacity
5kVA*3
Output terminal
Wire terminals
Protection
The electronic circuit quickly detects over-voltage, over-current, over-temperature, and lack of
equal automatic trip protection and alarm devices. The non-test state voltage is zero and the current is zero.
Display& Setting
Voltmeter display
True color LCD and digital display (display accuracy: 0.1V, display error: ≤1% ± 1 digital)
Ammeter display
True color LCD and digital display (5 digit digital display, display accuracy 0.1A, display error: ≤1% ± 1 digital)
System
Machine efficiency
≥90%
Withstand voltage insulation resistance
AC 1800V 1 minute, 20 megohms
Cooling device
forced fan cooling
Noise
<60dB (1mm in front of the machine)
Transformer accuracy
0.2 class
Protection level
IP20
Working environment
Working mode
long-term temperature rise experiment
Temperature
-10°C-50°C
Humidity
0-90% (non-condensing state)
Altitude
Below 1500m
Shape
Structure
Integration
Size
1.25*1.05*1.6 m
Bus bar
output is calculated as 2 currents per square
Temperature inspection
16-way module
Expandable
Class A thermocouple
About us