Test Instrument

Touch Screen Control Stable Rubber Mooney Viscometer Rheometer

Dongguan Haida Equipment Co., Ltd.
  • Type:Material Testing Machine
  • Maxcapacity:<1000KN
  • Accuracy Grade:0.5
  • Load Way:Electronic Load
  • Loading Method:Dynamic Load
  • Display:Digital

Base Info

  • Model NO.:HD-R811-1
  • Control:Computer Control
  • Weight:500-1000Kg
  • Power Source:AC220V
  • Temperature Measurement Range:Room Temperature-200 ºC
  • Temperature Measurement Accuracy:100~200 ºC,≤ ± 0.3 ºC
  • Equipment Weight:About 250kg
  • Dimensions:540 mm× 560 mm× 1120mm
  • Power:600W
  • Transport Package:Strong Plywood Case
  • Specification:ASTM, ISO, GB standard
  • Trademark:Haida
  • Origin:Dongguan, China
  • HS Code:9024109000
  • Production Capacity:150 Sets Per Month

Description

Basic Info.

Model NO. HD-R811-1 Control Computer Control Weight 500-1000Kg Power Source AC220V Temperature Measurement Range Room Temperature-200 ºC Temperature Measurement Accuracy 100~200 ºC,≤ ± 0.3 ºC Equipment Weight About 250kg Dimensions 540 mm× 560 mm× 1120mm Power 600W Transport Package Strong Plywood Case Specification ASTM, ISO, GB standard Trademark Haida Origin Dongguan, China HS Code 9024109000 Production Capacity 150 Sets Per Month

Product Description

Touch Screen Control Stable Rubber Mooney Viscometer Rheometer 


The introduction of HD-G811-1 vulcanizer:
Rubber rheometer  is the most widely used instrument in the rubber processing industry to control the quality of the rubber, rapid inspection and basic research on rubber. It provides accurate data for the optimal formula combination of rubber, and can accurately measure the scorch time, positive vulcanization time, vulcanization Index and parameters such as maximum and minimum torque.

The features of HD-G811-1 vulcanizer:
1. High temperature control precision and wide range. (± 0.3 ºC)
2. Clock programming function. (Setting and modification time)
3. Advanced technology switching power supply, wide voltage range.
4. Imported integrated circuits and control components.
5. All Chinese and English display.
6. Comply with the requirements of GB / T16584 (Testing the vulcanization characteristics of rubber with a rotorless vulcanizer) and ISO6502.

The powerful microprocessor adopts high quality imported chips. On the one hand, computers and microprocessors can obtain signals from torque sensors and record them on graphs. At the same time, the interface between the computer and the measurement and control module exchanges data and controls the temperature of the cavity.
A series of interlocking functions are adopted in the design of the Rotorless vulcanizer, including closing the plastic glass door. If the door is not closed, the mold cannot be closed. Only when the door is closed safely can the mold be closed. Work can only be carried out.


The advantages of HD-G811-1 vulcanizer compared with other models:
1. HD-G811-1 vulcanizer is more stable and accurate.
2. HD-G811-1 vulcanizer is cheap and beautiful.
3. HD-G811-1 vulcanizer has complete functions.
 

The standard parameters of HD-G811-1 vulcanizer: 
ItemParameter
Equipment aliasSulphurometer,rotorless sulphur transformer, rotorless vulcanization test instrument
DisplayDisplay in both Chinese and English
Temperature measurement rangeRoom temperature-200 ºC
Temperature measurement accuracy100~200 ºC,≤ ± 0.3 ºC
Temperature stability100~200 ºC,≤ ± 0.3 ºC
Setting range0~200 ºC, setting minimum unit:0.1 ºC
Temperature display range0~200 ºC, display resolution:0.1 ºC
Setting time range0-200 minutes,  setting minimum unit:1 minute
Automatic range switchingautomatically increase according to actual torque
Power supply50HZ, ~ 220V ± 10%, 50 ± 1Hz, must be well grounded
Compressed air0.4Mpa (4KG) controlled by pneumatic regulating valve
Swing frequency100 times / minute (about 1.7HZ)
Ambient temperaturenormal temperature -40 ºC, relative humidity less than 80%, no corrosive gas in the air
Qualityabout 250kg
Power600W
Dimensions540 mm* 560 mm* 1120mm
Executive standardASTMD5289-95 ISO6502-1999 (E) GB / T16584-1996
Touch Screen Control Stable Rubber Mooney Viscometer RheometerTouch Screen Control Stable Rubber Mooney Viscometer Rheometer

After-service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.

Why choose us? 
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator. 
2. Excellent After sale Service: 
18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller. 
3. Commitment: 
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us. 
4. Good Packaging: 
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc. 


Company Introduction:
Touch Screen Control Stable Rubber Mooney Viscometer Rheometer
Touch Screen Control Stable Rubber Mooney Viscometer Rheometer