GDCR4000A Digital Double-clamp Phase Volt-ampere Meter

HV Hipot Electric Co., Ltd.
  • Power supply:DC9V Alkaline dry battery LR6(1.5V AA size 6PCS)
  • Measurement range:Voltage: AC 0.00V~600V
  • Clamp opening:Sharp mouth: Φ8mm Round mouth: 35*40mm
  • Data storage:1500 groups
  • Transport Package:Standard Export Wooden Box
  • Specification:ISO, SGS

Base Info

  • Model NO.:GDCR4000A
  • Trademark:HV Hipot
  • Origin:Wuhan China
  • Production Capacity:100000 Sets,Year

Description

WeightMain unit: 550g (with battery)Sharp-mouth current clamp: 170g×2Round-mouth current clamp: 185g×2Test lead: 250gTest lead1.5mTest lead of current clamp2m×φ5mmWorking condition-10ºC~40ºC; <80%RHStorage condition-10ºC~60ºC; <70%RHInput impedanceInput impedance of test voltage: 1MΩWithstand voltageWithstand voltage AC 1000V/50Hz (sine wave) between instrument line and shell for 1 minute.Insulation Insulation between instrument line and shell ≥100MΩStructureDouble insulation, with shock-proof insulation sheath.Standard complianceIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2

Basic error and index under reference condition
ItemMeasurement rangeResolutionBasic error
VoltageAC 0.00V~600V0.01V±(0.5%F.S.)
CurrentAC 0.0mA~20.0A0.1mA±(0.5%F.S.)
Phase0.0°~360°0.1°±1°
Active power (P)0.0W~12kW0.1W±(1.0%F.S.)
Reactive power (Q)0.0var~12kvar0.1var±(1.0%F.S.)
Apparent power (S)0.0VA~12kVA0.1VA±(1.0%F.S.)
Power factor (PF)-1~+10.001±0.03
Frequency (F)45Hz~65Hz0.01Hz±(1.0%F.S.)

Note: Phase error under working condition: ±3° within 10mA~20A; ±6° below 10mA