Density Determination Apparatus by Hydrometer Method ASTM D1298
Temperature controllerRange:Ambient to 100ºCAccuracy:±0.2ºCSensor:Pt1006ThermometerMercury-in-glass thermometer. Scale division is 0.2ºC7Dimension560mm×380mm×580mm4.Detail Images:IV.Petroleum &Oil Analyzer Petroleum Testing InstrumentsOpen Cup Flash Point Tester
-
AU-2000K Digital Electronic Archimedes Gold Tester Machine, Densimeter For Gold, Gold Purity Densitometer
Basic Info. Model NO. AU-2000K
-
100kv Insulating Oil Dielectric Strength Tester Transformer Oil Breakdown Voltage Bdv Test Equipment
No.Item NameQTY1GDYJ-5021 Unit2Power line1 Unit3Grounding line1 Unit4Test vessel1 Unit5Electrodes(Mushroom, Flat and Spherical type)1paireach6Feeler gauge(1mm,2mm,2.5mm,4mm)1pc each7Stirrer2 units8High voltage column1pair9USB-RS232 connection line1 Unit10Thermal print paper2 units11Fuse(5A/3A)2 unit
-
Power Cord Plug Cable Harness Tester Power Cord Plug Cable Testing Machine
The system adopts advanced four-wire measurement, and the short-circuit judgment value is minimum 200Ω.High voltage (leakage current) test100~700VHigh voltage insulation test5~1000VDisplay/Alarm320x240 dpi graphic LED display Pass/Fail LED/Screen Display/AlarmMeasurement Connection256/512 Test
-
AU-120K 3 Years Warranty Original Factory Electronic Gold Analyzer, Gold K Value Analyzer, Gold Karat Purity Testing Machine
BrandQuarrzModelAU-300K / AU-600K / AU-900KAU-120K / AU-200KAU-1200K / AU-2000K / AU-3000KStyleHot and ClassicHigh-precisionHigh-capacityMaximum weight300g / 600g / 900g120g / 200g1200g / 2000g / 3000gWeight standard deviation0.005g / 0.005g /0.01g0.001g0.01gMinmum measuring sampleReference weight4g
-
in-Situ Direct Shear Test Apparatus of Rock and Soil
Dimension of shear box500mm×500mm×220mm; 700mm×700mm×280mJackNormal direction 300KN stroke 200mm;Tangential 500KN stroke 200mmPressure sensorResistance strain load cell, bridge resistance 350ΩMeasuring range: 0~300kN ~500kNOutput sensitivity: 2mV/VAccurac
-
Automatic Kinematic Viscosity Bath Apparatus with Standard Capillary Viscometer
ParameterGD-265CGD-265D-1GD-265GGD-265HAuto./ManualManualSemi-automaticManualAutomaticTemperature rangeAmbient~100ºCAmbient~100ºCAmbient~-70ºC with compressor for refrigerationAmbient~100ºCTemp. control precision±0.1ºC±0.01ºC±0.1ºC±0.01&
-
Oil Kinematic Viscosity Analyzer ASTM D445
ParameterGD-265CGD-265D-1GD-265GGD-265HAuto./ManualManualSemi-automaticManualAutomaticTemperature rangeAmbient~100ºCAmbient~100ºCAmbient~-70ºC with compressor for refrigerationAmbient~100ºCTemp. control precision±0.1ºC±0.01ºC±0.1ºC±0.01&