200kV 30kVA Withstand Test Automatic PLC AC Hipot Test Set
HV Hipot Electric Co., Ltd.- Voltage:AC 200kV, customized
- Current:150mA
- Capacity:30kVA, customized
- Control unit:PLC control
- Transport Package:Standard Export Wooden Box
- Specification:ISO, SGS
Base Info
- Model NO.:GDYD-2030A
- Trademark:HV Hipot
- Origin:Wuhan, China
- Production Capacity:5000set,Year
Description
Basic Info.
Model NO. GDYD-2030A Trademark HV Hipot Origin Wuhan, China Production Capacity 5000set/YearProduct Description
200kV 30kVA Withstand Test Automatic PLC AC Hipot Test SetI. General information
GDYD-2030A Automatic AC/DC Hipot Test Set is composed of automatic control unit and gas testing transformer (HV unit) which output AC or DC voltage smoothly. Meanwhile, it has many monitoring and protection functions.
II. Features
- 7inch color LCD screen, with PLC automation control.
- HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip
- Automatic mode and manual mode for option.
- Display HV voltage, LV voltage, LV current, time and withstanding result.
- Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set.
- Zero-starting function. Test can be proceeded after the voltage is back to zero.
- Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk.
- When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero.
- When the LV current is over setting value, the voltage will be cut off automatically and it will be back to zero. When the HV current is over setting value, the test object will be cut off and test can be proceeded continuously.
- With anti-interference ability, suitable for electromagnetic environment.
- With wheels for both control unit and HV unit, easy to move.
III. Specifications
- Control unit specifications
- Power: AC380V, 60Hz
- Capacity: 30kVA
- Output voltage: AC 0-430V
- Rated output current: 75A
- Rated current rectified range: 0-75A
- HV voltmeter range: 0-200kV
- HV ammeter range: 0-100mA
- LV ammeter range: 0-25A
- Timing range: 1s-99h
- Weight: about 116kg
- Dimension: 540mm (L)*600mm (W)*1140mm (H)
B. Testing transformer (HV unit) specifications
- Input voltage: 0-400V
- Input current: AC 0-75A
- Output voltage: AC 0-200kV, DC 0-200kV
- Output current: AC 150mA, DC 106mA
- Capacity: 30kVA
- HV side/LV side turns ratio: 500:1
- Measuring voltage: AC 0-100V
- No-load current: <10%
- Impedance voltage: <10%
- Weight: about 180kg
- Dimension: 630mm(D)*1730mm(H)
C. Working conditions
- Working place: No gas, steam, chemical dust and explosive and corrosive medium which will influence insulation.
- Environment temperature: -20--50ºC
- Environment humidity: ≤85% RH (no condensing)