Environmental Walk in Constant Temperature Humidity Test Room/Stability Chamber
Ai Si Li (China) Test Equipment Co., Limited- After-sales Service:Lifelong Technical Service Support
- Power Supply:AC380V
- Certification:CE, TUV, ISO
- Warranty:1 Year
- Temperature Range:-70~+150 Degree C
- Humidity Range(Optional):20%~98%R.H.
Base Info
- Model NO.:THR Series
- Temp. Rising Speed:0.1~3.0degree C,Min
- Temp.Falling Speed:0.1~1.5degree C,Min
- Analytic Accuracy:0.1degree C; 0.1% R.H
- Uniformity:+,-2.5degree C
- Control Accuracy:+,-0.5degree C
- Cooling System:Water Cooling
- Type:Reliability Test
- Transport Package:Wooden Case
- Specification:THR Series
- Trademark:ASLi
- Origin:Guangdong, China
- HS Code:85141910
- Production Capacity:300 Sets, Year
Description
Overview
Product Description
• Remote fault notification(optional)
• With Viewing Window
• With Data Storage function by USB Flash Memory
• Protection (phase protection, overheat, over current etc)

Application:
Environmental Walk in Constant Temperature Humidity Test Room/Stability Chamber is used to test various types of materials for their tolerances of heat, cold, dry, humidity. It is applied for quality inspection for all types of big test samples, such as electronic products, electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical, building materials, medical and aerospace industries.Product ParametersEnvironmental Walk in Room fTechnical Parameters Model THR-volume (low-temperature options : A ~ F) Inner Dimensions(cm) Customers designated space size and design Temperature Range Low Temperature(A:25degree C B:0degree C C:-20degree C D:-40degree C
E:-60degree C F:-70degree C ) High Temperature 80degree C
(80degree C ~150degree C is optional) Humidity Range 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier) Indication Resolution/
Distribution Uniformity of
Temperature & Humidity 0.1degree C ; 0.1% R.H/±2.5degree C ; ±3.5% R.H. Control Accuracy of
Temperature and Humidity ±0.5degree C ; ±2.5% R.H. Temperature Rising/
Falling Velocity Temperature rising approx. 0.1~3.0°C/min;
temperature falling approx. 0.1~1.0°C/min;
( The Falling Velocity Min.1.0°C /min is a optional) Cooling System Water cooled Protection Devices Fuse-free switch, overloading protection switch for compressor,high and low voltage coolant protection switch, over-humidity & over-temperature protection switch, fuses, fault warning system, water short storage warning protection Optional Accessories Slope for cart , Recorder, Water Purifier, Dehumidifier Compressor French Tecumseh Brand, Germany Bizer Brand Power AC 380 V(±10%),50/60HZ ,3 phase 5 Lines
Environmental Walk in Room Features:
1. Graceful appearance, circularly shaped body, surface treated with mist strips and plane handle with no reaction. Easy to operate, safe and reliable.
2. Rectangular double-paned viewing window for the observation of sample under test with interior lights
3. Double-layer-insulated airtight doors, able to insulate the internal temperature effectively.
4. Water supply system that is externally connectable, convenient for refilling water into the humidifying pot and automatically recyclable.
5. French Tecumseh brand is used as compressor, with environment friendly refrigerationR23, R404A
6. LCD display screen, capable of displaying the set point and actual value at the same time
7. The control unit has the functions of multiples segment program editing, with ramp rates control of temperature and humidity.
8. Casters are provided for ease of mobility, with strong positioning screws.Detailed Photos
• With RS485/232 output to computer
• Window Software• Remote fault notification(optional)
• With Viewing Window
• With Data Storage function by USB Flash Memory
• Protection (phase protection, overheat, over current etc)

Application:
Environmental Walk in Constant Temperature Humidity Test Room/Stability Chamber is used to test various types of materials for their tolerances of heat, cold, dry, humidity. It is applied for quality inspection for all types of big test samples, such as electronic products, electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical, building materials, medical and aerospace industries.Product ParametersEnvironmental Walk in Room fTechnical Parameters
E:-60degree C F:-70degree C ) High Temperature 80degree C
(80degree C ~150degree C is optional)
Distribution Uniformity of
Temperature & Humidity
Temperature and Humidity
Falling Velocity
temperature falling approx. 0.1~1.0°C/min;
( The Falling Velocity Min.1.0°C /min is a optional)
Environmental Walk in Room Features:
1. Graceful appearance, circularly shaped body, surface treated with mist strips and plane handle with no reaction. Easy to operate, safe and reliable.
2. Rectangular double-paned viewing window for the observation of sample under test with interior lights
3. Double-layer-insulated airtight doors, able to insulate the internal temperature effectively.
4. Water supply system that is externally connectable, convenient for refilling water into the humidifying pot and automatically recyclable.
5. French Tecumseh brand is used as compressor, with environment friendly refrigerationR23, R404A
6. LCD display screen, capable of displaying the set point and actual value at the same time
7. The control unit has the functions of multiples segment program editing, with ramp rates control of temperature and humidity.
8. Casters are provided for ease of mobility, with strong positioning screws.Detailed Photos