Test Instrument

Single Cable Vertical Flammability Tester Full Size for Burning Test En 50086-1

Delta Technology (Chongqing) Co., Ltd.
  • After-sales Service:Response on Customers′ Questions Within 12 Hours.
  • Warranty:12 Months
  • Description:Single Cable Vertical Flammability Tester
  • Reference Standards:IEC60332-1-2, IEC60332-1-3
  • Function:Measure Resistance of Single Cable to 1kw Flame
  • Application Field:Cable, Wire

Base Info

  • Model NO.:SCV
  • Features:China Low Price Cable Vertical Flammability Tester
  • Stainless Steel Box Dimension:1300mm(H) * 300mm(W) * 450mm(D)
  • Burner:1kw
  • Dimension:560 mm (W) X 380 mm (D) X 1400 mm (H)
  • Weight:36kg
  • Gas Supply:Air and Propane
  • Power Supply:110V AC 60Hz , 230V AC 50Hz
  • Delivery Lead Time:30 Days
  • Trade Term:Fob, CIF, DDU, EXW
  • Payment Term:30% T,T as Deposit, The Balance Before Delivery
  • Shipping Method:by Air or Express
  • Transport Package:Vertical Flammability Tester Packed in Veneer Case
  • Specification:560 mm (W) x 380 mm (D) x 1400 mm (H)
  • Trademark:Delta
  • Origin:China Mainland
  • HS Code:9031809090
  • Production Capacity:100 Sets Cable Vertical Flammability Tester, Month

Description

Overview Product Description

SCV Single Cable Vertical Flammability Tester is used for the vertical flame propagation of a single insulated wire or cable testing, to determine the resistance of a single cable to a 1kW flame application.

SCV Single Cable Vertical Flammability Tester conforms to IEC60332-1-2 (flame propagation) and IEC60332-1-3 (test for flaming droplets).

Product ParametersFeaturesStainless steel box, the height of 1300mm, width of 300mm, depth of 450mm.

Two stainless steel rods, can bind single wire cable or optical cable sample.

1KW mixed standard burner, can provide the standard test fire source.
Regulating gas and air flow rate of the rotor flow meters.

Pressure gauge and pressure relief valve to ensure that the pressure output is 0.1MPA.

Electric spark ignition device. Flame height measuring tool.

Up to four time modes can be selected according to different sample diameters.

Calibration kit for the testing flame.Single Cable Vertical Flammability Tester Full Size for Burning Test En 50086-1