Quality and Volume Test Mvr Plastic Testing Machine
Jinan Kason Testing Equipment Co., Ltd.- Display:LCD Display
- Sample Cutting Method:Automatic or Manual
- Test Method:Quality and Volume Test
- Weight Number:8 PCS
- Relative Error of Test Loa:0.1%
- Power Supply:220V,50Hz
Base Info
- Model NO.:XNR-400D
- Resolution:0.1c
- Accuracy:0.1c
- Testing Material:PP, PE, POM, ABS Plastics and Plastic Productions
- Gw:70kg
- Transport Package:Standard Exporting Plywood Case with Free Fumigati
- Specification:600*700*800MM
- Trademark:HST or OEM
- Origin:China
- HS Code:90248000
- Production Capacity:500 Sets,Month
Description
Basic Info.
Model NO. XNR-400D Resolution 0.1c Accuracy 0.1c Testing Material PP, PE, POM, ABS Plastics and Plastic Productions Gw 70kg Transport Package Standard Exporting Plywood Case with Free Fumigati Specification 600*700*800MM Trademark HST or OEM Origin China HS Code 90248000 Production Capacity 500 Sets/MonthProduct Description
XNR-400D Quality and Volume Test Mvr Plastic Testing Machine
Application:
XNR-400D Melt Flow Index Tester is accordance to ISO1133; GB3682-2000, ASTM D1238. It's suitable to measure melt flow character of PP, PE, POM, ABS plastics and plastic productions, widely used in factories, products quality testing station, scientific and research institutes, and concerned industries.
Advantages:
1. LCD display
2. Automatic & Manual both sample cut, load
3. Chinese & English version
4. Quality & Volume test
Main Specification:
Extrusion discharging part:
Diameter of discharging outlet: Φ2.095±0.005mm
Length of discharging outlet: 8.000±0.025mm
Diameter of charging barrel: Φ9.550±0.025mm
Length of charging barrel: 152±0.1mm
Diameter of piston rod head: Φ9.475±0.015mm
Length of piston rod head: 6.350±0.100mm
Standard load of test (eight class)
Grade 1: 0.325kg=(piston rod + scale pan+ lagging + No.1 weight=3.187N
Grade 2: 1.200 kg=(0.325+ No.2 weight 0.875)=11.77 N
Grade 3: 2.160 kg=(0.325+ No.3 weight 1.835)=21.18 N
Grade 4: 3.800 kg=(0.325+No.4 weight 3.475)=37.26 N
Grade 5: 5.000 kg=(0.325+ No.5 weight 4.675)=49.03 N
Grade 6: 10.000 kg=(0.325+No.5 weight 4.675+No.6 weight 5.000)=98.07 N
Grade 7: 12.500 kg=(0.325+No.5 weight 4.675+No.6 weight 5.000+ No.7 weight 2.500)=122.58 N
Grade 8: 21.600 kg=(0.325+No.2 weight 0.875+No.3 weight 1.835+No.4 weight 3.475+No.5 weight 4.675+No.6 weight 5.000+No.7 weight 2.500+No.8 weight 2.915)=211.82 N
A. Relative error of test load≤0.1%
B. Range of temperature: Room temperature 50---450ºC.
C. Accuracy of constant temperature:±0.1°C
D. Power supply:220V±10%,50Hz
E. Working environment: The temperature is 10°C-40°C, relative humidity is 30%-80%, no corrosive medium around, no strong air convection, no shake, no disturb from magnetic field
F. Resolution:0.1ºC
F. Overall dimension (L x W x H)(mm):510×370×600
G. Host weight: 25kgs weights: 21.6kgs TEL: 8615098778967