2V 6V 12V Battery Charge Discharge Activator for Storage Battery
HV Hipot Electric Co., Ltd.- Single cell voltage measurement type:2V,6V,12V
- Single cell voltage measurement range:2V: 0~3V, 6V,12V: 0~16V
- Voltage measurement accuracy:0.5%
- Working voltage:AC 220±15%
- Heat transfer:Forced air cooling
- Dimension:401mm * 176mm * 273 mm
Base Info
- Model NO.:GDKH-12
- Weight:15kg
- Transport Package:Wooden Case
- Specification:ISO, SGS
- Trademark:HVHIPOT
- Origin:Wuhan China
- Production Capacity:2000sets,Year
Description
Single cell voltage measurement type
2V/6V/12V
Single cell voltage measurement range
2V: 0~3V 6V/12V: 0~16V
Single cell voltage resolution
2V: 0.001V; 6V/12V: 0.001V
Voltage measurement accuracy
0.5%
Charge/discharge current range
2V: 1A~100A 6V: 1A~ 30A 12V: 1A~ 30A
Charge/discharge current control accuracy
1%
Battery capacity checking range
2V: 20Ah~ 1000Ah
6V: 20Ah~300Ah
12V: 20Ah~300Ah
Working voltage
AC 220±15%
Heat transfer
Forced air cooling
Working environment
Temperatures: 0ºC~40ºC humidity:20%~80RH
Storage conditions
-20ºC~+70ºC packaged storage
Display
High light LCD screen
Dimension
401mm * 176mm * 273 mm
Weight
15kg