Test Instrument

Laboratory Temperature Test Cold Hot Shock Testing Equipment

Dongguan Haida Equipment Co., Ltd.
  • Warranty:1 Year
  • Type:Test and Measurement Instruments
  • Accuracy Grade:0.5
  • Display:Digital
  • Control:Computer Control
  • Weight:500-1000Kg

Base Info

  • Model NO.:HD-E703
  • Power Source:AC220V
  • Certificate:ISO9001: 2008,SGS,Ce
  • Controller:LCD Touch Screen
  • Box Material:Stainless Steel
  • Warranty Period:One Year
  • Delivery:20 Days After Receive The Deposit
  • Model:HD-50tst
  • Interal Dimension:(W* H* D) 36*35* 40cm
  • Outside Dimension:151* 182* 142cm
  • Damper Device:Forced Air Drived Damper
  • Cooling Method:Air or Water
  • Transport Package:Strong Wooden Case
  • Specification:ISO9001: 2008
  • Trademark:Haida
  • Origin:Dongguan, China
  • Production Capacity:150 Sets,Month

Description

Basic Info.

Model NO. HD-E703 Power Source AC220V Certificate ISO9001: 2008,SGS,Ce Controller LCD Touch Screen Box Material Stainless Steel Warranty Period One Year Delivery 20 Days After Receive The Deposit Model HD-50tst Interal Dimension (W* H* D) 36*35* 40cm Outside Dimension 151* 182* 142cm Damper Device Forced Air Drived Damper Cooling Method Air or Water Transport Package Strong Wooden Case Specification ISO9001: 2008 Trademark Haida Origin Dongguan, China Production Capacity 150 Sets/Month

Product Description

                                 Laboratory Temperature Test Cold Hot Shock Testing Equipment

Temperature Shock Tester is used to test most commercial products to see how they withstand drastic temperature changes. A thermal shock chamber will subject a product to the most extreme temperature conditions, instantly.

The purpose of testing a product under these circumstances by the thermal shock test chamber is to observe changes in the products characteristics and check for failure occurrence of different materials and thermal expansion coefficients.

 
  Model  HD-E703
  Interal Dimension  (W× H× D) 36× 35× 40cm
  Outside dimension  151× 182× 142cm
  Structure  Three chambers design (the hot chamber, the cold chamber and the testing chamber)
  Damper device  Forced air drived damper
  Interior material  SUS#304 Stainless steel plate
  Exterior material  SUS#304 Stainless steel plate
  Basket material  SUS#304 Stainless steel plate
  Refrigeration  Cascade refrigeration system
  Cooling method  Air or Water
  Ambient temperature  0  ºCto 30  ºC
  Preheating temperature  +60.ºC to +200.ºC
  Precooling temperature  -10.ºC  to -70.ºC
  H. T. Shocking  +60.ºC to +150.ºC
  L. T. Shocking  -10.ºCto -65.ºC
  Temperature uniformity  ± 2.ºC
  Simulated load ic  5.0kg
  HT IN-Zone  -65.ºC to +150.ºC/5min
  LT IN-Zone  +150 ºC to -65.ºC
  Preheating time  30MIN
  Precooling time  60MIN
  Senor  T× 4
  Controller  OYO-8226
  Setting range  Temperature: -100.ºC to +200.ºC  TIME: OHIM to 999H/CYCLE: 0 to 9999
  Resolution  Temperature: 0.1 ºC
  Output mode  PID+SSR (control method)
  Power(K. W)  AC380V 50HZ 18KW

Features:
  1. Perfect appearance and easy to operate.
  2. Japan LCD English microcomputer temperature controller, with high memory capacity, can save 100 programs, max 9999 cycles, each cycle max time 999hrs.
  3. Three chamber structures, high temperature chamber, low temperature chamber and test chamber, control automatically, stay and switch time adjustable.
  4. Perfect protection alarm functions: short-circuits, Leakage, over temperature of work chamber; compressor over pressure, over load, short water…
  5. Control interface will display alarm reason and provide check methods, machine has emergency stop button.
  6. Cold and hot shock temperature recover within 5 minutes, which complies with MTL, IEC, JIS, GJB and other international standards.
  7. With RS-232C communication port for connecting PC to control, record and save test report.
Laboratory Temperature Test Cold Hot Shock Testing Equipment

Laboratory Temperature Test Cold Hot Shock Testing Equipment

Why choose us? 
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator. 
2. Excellent After sale Service: 
18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller. 
3. Commitment: 
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us. 
4. Good Packaging: 
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc. 

Laboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing EquipmentLaboratory Temperature Test Cold Hot Shock Testing Equipment