Gas Chromatography Tester for Indoor Environment Voc Testing
Dongguan Haida Equipment Co., Ltd.- Warranty:1 Year
- Type:Gas Chromatography Machine
- Accuracy Grade:0.5
- Display:Digital
- Control:Computer Control
- Weight:0-100Kg
Base Info
- Model NO.:HD-R827
- Power Source:AC220V
- Dimensions:250 mm *250 mm * 176 mm(W*D*H)
- Temperature Control Accuracy:0.5% (± 0.1 ºC)
- Data Communication Interface:1 RS232 Interface, 1 RS232 Communication Line
- Detector (Optional):6 Types
- Purpose:Separation and Analysis Tools for Multicomponent M
- Transport Package:Strong Wooden Case
- Specification:HD-R827
- Trademark:Haida
- Origin:Guangdong, China
- Production Capacity:100 Set Per Month
Description
Detector: 6 kinds of detectors are optional, and 3 detectors and 3 magnifying plates are installed at the same time without disassembly.1. Hydrogen flame detector FID: Suitable for packed column / capillary column analysis
Host or workstation control automatic ignition Temperature control range Room temperature + 5 ºC -400 ºC Minimum detection limit ≤5 x 10-12 g / s (n-hexadecane) Baseline noise ≤5 x 10-14 A Baseline drift ≤1 x 10-13 A (30 min) after turning on and stabilizing for 150 minutes 2. Thermal conductivity detector TCD: Two-column equilibrium method, suitable for packed column analysis (need to select 2 packed column injectors at the same time) Temperature control range Room temperature + 5 ºC -400 ºC Sensitivity ≥10000mV • ml / mg (n-hexadecane) Detection limit ≤6 x 10-9 g / ml Baseline noise ≤0.03mV (the carrier gas is 99.999% hydrogen) Baseline drift ≤0.1mV / 30min after starting and stabilizing for 150 minutes 3. Flame photometric detector: Suitable for packed column / capillary column analysis
Host or workstation control automatic ignition Maximum operating temperature 400 ºC Minimum detection limit ≤1 x 10-10 g / s (sulfur in methyl parathion) Minimum detection limit ≤1 x 10-11 g / s (phosphorus in methyl parathion) Baseline noise ≤8 x 10-11 A Baseline drift ≤5 x 10-12 A (30 min) after turning on and stabilizing for 150 minutes 4. Electronic capture detector (ECD): Suitable for packed column / capillary column analysis, with ECD environmental protection exemption certificate Detection limit ≤3 x 10-14 g / ml (BHC) Baseline noise ≤15 μV Baseline drift ≤50μV / 30min after starting and stabilizing for 150 minutes Radioactive source Ni 63 ≤10 mCi (millicuries) 5. NPD detector: Temperature control range Room temperature + 5 ºC -400 ºC Detection limit N≤5 x10-12g / s (azobenzene), P≤5 x 10-13g / s (malathion) Baseline noise ≤2 x 10-13A Baseline drift ≤4 x 10-13A / 30 min after starting and stabilizing for 150 minutes 6. PID of photoionization detector Detection limit ≤5 x 10-12 g / ml Baseline noise ≤5 x 10-14A Baseline drift ≤1.2 x 10-12A (30 min)
Application:
1. Analysis of dissolved gas in transformer oil;
2. Analysis of ethylene oxide in medical devices
3. Coke oven gas analysis;
4. Pesticide residue analysis;
5. Analysis of alcohol in the blood;
6. Analysis of natural gas and LPG;
7. Indoor environment TVOC analysis;
8. Composition analysis of liquor;
9. High purity gas analysis;
10. Packaging material solvent residue detection.
The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.









Host or workstation control automatic ignition
Host or workstation control automatic ignition
Application:
1. Analysis of dissolved gas in transformer oil;
2. Analysis of ethylene oxide in medical devices
3. Coke oven gas analysis;
4. Pesticide residue analysis;
5. Analysis of alcohol in the blood;
6. Analysis of natural gas and LPG;
7. Indoor environment TVOC analysis;
8. Composition analysis of liquor;
9. High purity gas analysis;
10. Packaging material solvent residue detection.
The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.