Test Instrument

GD2136H 0~32kV Cable Fault Detecting System

HV Hipot Electric Co., Ltd.
  • Test Mode:Impulse Flashover Method
  • Usage:Power Cable Test
  • Test Region:0~35kv
  • Cable Type:Shielded
  • Power:Electricity
  • Certification:ISO

Base Info

  • Model NO.:GD2136H
  • Customized:Customized
  • Color:Yellow
  • Input Power Supply:AC 220V, 50Hz
  • Output Voltage:DC 0-32kv (Adjustable)
  • Max.Testing Distance:5km(Open Wire up to 100km) According to Customer′s
  • Blind Detection:1m
  • Resolution:1m
  • Power Consumption:5va
  • Environmental Temperature:0-40degree(Limit Temperature:-10degree-50degree)
  • Transport Package:Wooden Case
  • Specification:ISO, SGS
  • Trademark:HV Hipot
  • Origin:China
  • HS Code:9030332000
  • Production Capacity:1000PCS,Year

Description

Tracing and locating distancelocal cable 3km, other cable up to 20kmFault impedance resistance 0-5MΩLocating accuracy: ≤±10cmDetection cable depth<3m
 
GD-2133 Cable Fault Detector
It can test faults of short circuit, grounding, high impedance leakage, high impedance flashover fault and cable's poor connection, disconnection for all kinds of power cables (voltage degree 1kV-35kV), local cable, communication cable, coaxial-cable and metal overhead line. It also can measure cable's length and propagation speed of electric wave speed on the cable. 

 
Features
l Safe, prompt and accurate testing. It uses LV impulse method and HV flashover detection, which test all kinds of cable faults. 
l Using high speed data sampling technology. A/D sampling speed is 100Mhz. 
l Wave form and data automatically display on big LCD screen. 
l Wave form and parameter storage function. 
l Function of comparing testing waveform of cable fault with normal waveform. 
l Wave form extending function. 
l Directly show fault point and testing point direct distance or relative distance. 
l Modify speed of propagation any time according to different testing cables. 
l Built-in rechargeable battery. Small size, portable to carry. 

 
Specifications

 Max. testing distance15km(Open wire up to 100km) according to customer's requirements. Blind detection1mResolution1mPower consumption 5VAEnvironmental temperature0-40 degree (limit temperature: -10-50 degree)Relative humidity40 degree (20~90)%RH