Test Instrument

Rebar Location and Corrosion Measuring System

Zhuozhou Tianpeng Imp. & Exp. Trade Co., Ltd.
  • Transport Package:Carton Box
  • Trademark:C-tech
  • Origin:China

Base Info

  • Model NO.:GW-50B
  • HS Code:90248000
  • Production Capacity:500sets,Month

Description

ModelGX-50BApplicable steel-bar diameterdia.6mm~dia.50mmTested range of concrete cover thicknessLow range:6mm~90mm;
High range:7mm~180mmTested range of Steel-bar diameter
dia.6mm~dia.50mm
 Permissible error of Steel-bar diameter±1 gradeWorking environmentTemperature:-10°C~+40°C Dampness:<90%RH EMI: no Strong electromagnetic fieldPower supply6 dry cells,work more than 30 hours
Corrosion specification
1.  Automatically monitor the ambient temperature without the help of thermometer.
2. Permanently fixed cupric sulfate-copper electrode. No need to perfuse and change cupric sulfate saturated solution both before and after the test, in order to avoid damage to the environment and testers.
3. Two measurement methods: potential method and gradient method, with potential electrode and gradient electrode respectively.
4. Measuring Potential:  ±2000mV;
5. Test accuracy: ± 1mV;
6. Measuring Space: 1-99 cm (adjustable)
7. Environment Requirement: Ambient Temperature:-10°C~+40°C, to avoid direct exposure to the sun for a long time. Relative Humidity:<90%RH; Electromagnetic Interference: no strong alternating electromagnetic field.

Rebar Location and Corrosion Measuring System